Cum diiudicatio inter lens plano-convexam et lens bi-convexam, quarum utraque causa in lucem incidentes collimatur ad conglobandum, praeponenda est plerumque lens plano-convexum eligere, si magnificatio absoluta desiderata vel minor quam 0,2 vel maior quam 5 est. .
Ob latitudinem transmissionis extensionem (2 – 16 µm) et stabilium chemicorum proprietatum, Germanium applicationibus laseris IR aptissimum est, est optimum ad securitatem, ad applicationes militares et ad imaginationem. Sed proprietates tradendae Ge s sunt valde temperatus sensitivo; re vera effusio tanta fit ut germanium in C°C fere opaca sit, et omnino non-transmissivum in CC °C.
Optica paralight offert Germanium (Ge) Plano-convexum (PCX) Lentium in promptu cum latitudine AR efficiens pro 8 µm ad 12 µm ambitum spectris in utraque superficie depositum. Haec efficiens multum remittit altam superficiem reflexionis subiecti, praebens mediocris transmissio in excessu 97% super totam range AR efficiens. Compesce Graphs pro indiciis tuis.
Germanium
Uncoated vel cum DLC & Antireflectivis Coatings Optimized pro 8 - 12 μm Range
Praesto ab 15 ad 1000 mm
Praeclara Securitatis, Militaris, et Imaginis Applications
Substratum Material
Germanium
Type
Plano-Convex (PCX) Lens
Index Refractionis
4.003 @ 10.6 μm
Abbatis Number (Vd)
Non definitur
Scelerisque Expansion Coefficient (CTE)
6.1 x 10-6/
Diameter Tolerantia
Precision: +0.00/-0.10mm | High Precision: +0.00/-0.02mm
Crassitudo tolerantia
Precision: +/-0.10 mm | Subtilitas alta: +/-0.02 mm
Arx Longitudo Tolerantia
+/- 1%
Superficiem Quality (Scratch-Dig)
Precision: 60-40 | High Precision: 40-20
Superficiem idipsum (Plano Latus)
λ/4
Sphaericum Superficiem Power (Convex Side)
3 λ/4
Superficies Irregularitas (Peak ad Valley)
λ/4
Centration
Precision:<3 arcmin | Alta praecisio: <30 arcsec
Patet Apertura
> 80% Diametri
AR Coating Range
8 - 12 μm
Transmissio super Coating Range (@ 0° AOI)
Tavg > 94%, Tabs > 90%
Meditatio super Coating Range (@ 0° AOI)
Ravg<1%, Rabs< 2%
Design Wavelength
10.6 μm
Laser damnum Limen
0.5 J/cm2(1 ns, 100 Hz, @10.6 μm)